Instruction ManualDT-5TXR / DT-5TSDIGITAL PANEL MOUNT TACHOMETER
10Mode -03- (Process Time Measurement)The following parameters must be set in mode -03- so that the DT-5TXR/DT-5TS will display the correct readings:I
11Setting High and Low LimitsIf the variation of motor speed or time measurement is important and a “range” must be monitored, then “high” and“low” vi
12Setting Functions (continued)Instructions to set functions are as follows:1. Press the FUN button; the display will indicate:NOTE: The display will
13Setting ExamplesMODE -01- (RPM or Rate Measurement)The DT-5TXR/5TS units are fully scalable, which means thatRPM can be used to display linear spee
14Setting Examples (continued)MODE -03-This mode is used to measure the time a process takesfrom start to finish. An example could be a CNC machineth
15Modules Available for DT-5TXRA variety of modules are available to provide an array ofoutput and input options when using the DT-5TXR.Most of the mo
16All outputs should be isolated through an opto-coupler.Each transistor can handle up to 30VDC and no morethan 20mA.DT-5TXR with DOP-TRTR ModuleDT-5T
17DT-5TXR-FVTR/DT-5TXR-FVC (continued)Instructions to set the analog output characteristics areas follows:1. Press the FUN button eleven times; the di
18The waveforms below give a synopsis of how the outputBCD data behave during the time the different controlfunctions become active.The waveforms show
19DImensions and SpecicationsMODELModereteM etaR / retemohcaTElapsed Time Process Time0:00:00 - 9:59:59 0:00:00 - 0:59:59or or0.00 - 999.99 s ec 0.00
2Congratulations on your purchase of a Shimpo DT-5TXRor DT-5TS digital panel mount tachometer. Whethermeasuring RPM or a complex function, we tr
20WarrantyLIMITED EXPRESS WARRANTYShimpo Instruments warrants, to the original purchaser of new products only, that this product shall be free from de
3Important Safety PrecautionsStandard AccessoriesIf any damage is apparent, do not unpack the panelmeter. Notify the shipping carrier
4Display and KeypadNOITCNUFNOITANGISED.ONnoitcnuf yromem setavitcAnottuB yromeM.1detavitca si noitcnuf yromem nehw NOrotacidnI yromeM.2edom putes gnil
5Set-UpPowerRefer to diagram 1 (right) for location of the terminals.AC ModelsApply 85 – 264 VAC, 50/60 Hz between terminals 1 and 2.DC ModelsApply 9
6Factory SettingsThe following charts reflect the default parameter and function settings as programmed by the factory:Operating Mode -01- (RPM or Rat
7OperationMode Operation SelectionDepending upon the type of application, the DT-5TXR/DT-5TS offers different modes of operation; these modes andthei
8Mode -01- (RPM or Rate Measurement) continuedSet the parameters in mode -01- as follows:1. Press the PAR button; the display will indicate:The “-01-
9Mode -02- (Elapsed Time Measurement/Monitoring)The following parameters must be set in mode -02- so that the DT-5TXR/DT-5TS will display the correct